ZKTEK provides all kinds of custom OEM/ODM ATM machine,interactive kiosk,information kiosk, touchscreen kiosk, touchscreen monitor, touchscreen computer, box ipc,digital sginages, pos and metal keyboard products
The integrated multifunctional health check kiosk has a reasonable sleek and slim layout, sophisticated structure, convenient use, combined with the innovation check methods, perfect business philosophy, It has won the widespread favor of domestic and foreign customers.
The integrated multifunctional health check kiosk has a reasonable sleek and slim layout, sophisticated structure, convenient use, combined with the innovation check methods, perfect business philosophy, It has won the widespread favor of domestic and foreign customers.
The multifunctional health check kiosk is a luxury machine integrated with equipment to test blood pressure, blood oxygen, blood glucose, uric acid, cholesterol, ECG, specially developed for medical treatment, health center, community health center and health department. It has humanized touch operation, quick and accurate measurement and detecting result, in-built 15 inch high-definition touch screen and 21 inch advertisement screen, intelligent voice prompt and so on.
Test Items |
Specifications |
||
Weight |
System |
resistance strain type |
|
Index |
Automatic intelligent index calculator |
||
Range |
1~300kg |
||
Precision |
±0.1kg |
||
Sensitivity |
d=±0.04Kg |
||
Height |
System |
Ultra sonic non-touch type |
|
Range |
60.0~210cm |
||
Precision |
±0.1cm |
||
Sensitivity |
±0.1cm |
||
Blood Pressure |
Device |
Automatic Electronic blood pressure meter |
|
Measurement type |
Oscillometric method |
||
Adjustment range |
User-defined height rang:80cm--135cm; Angle range: 15°-45° |
||
Arm circumference value |
17cm--42cm |
||
System |
Oscillometric measurement,Intelligent pressurization technique, silent measurement process |
||
Range |
Pressure :0~300mmHg,(0~40Kpa);Pulse:40/minute~190/minute |
||
Precision |
Pressure :within ±2mmHg(±0.3kpa),Pulse:Within ±2% |
||
Sensitivity |
±2mmHg |
||
Body fat |
Equipment |
Body fact device |
|
Test System |
Multi frequency 4- electrodes |
||
Frequency |
5kHz/50kHz/250kHz/500kHz |
||
Current |
90μA or below |
||
Electrode material |
Electroplate material |
||
Range |
75.0~1,500.00Ω(0.1Ω) |
||
Detect part |
Body, leg, arm |
||
|
Sensitivity |
±0.1Ω |
|
Blood Oxygen |
Device |
Blood Oxygen tester |
|
Range |
35-100%(±2% normal ,±3% Exercise or weak perfusion ) |
||
Error |
±2% |
||
Body Temperature |
Device |
Temperature tester |
|
Measurement Method |
Infrared sensor |
||
Range |
Human body: 32.0-42.5℃ Surface temperature : 0-100℃ Precision:0.1º C |
||
Sensitivity |
±0.1º C |
||
Blood glucose |
Device |
blood glucose tester |
|
Range |
1.1-33.3mmol/L(20-600mg/dL) |
||
Time |
5s±0.5s |
||
Precision |
±0.3(Standard resistance bar test) |
||
Display method |
mmol/Lx display and test time |
||
Sensitivity |
±0.3mmol/Lx |
||
12 Lead ECG Tester |
Device |
ECG tester |
|
Lead |
Standard 12 leads |
||
Input method |
Vibration-proof protection input |
||
Collection Method |
12 leads simultaneous collection |
||
Range |
±5mVpp |
||
Time constant |
≥3.2s |
||
Frequency response |
0.05Hz~150Hz(-3dB) |
||
Sensitivity |
2.5 mm/mV, 5 mm/mV, 10 mm/mV, 20mm/mV |
||
Input impedance |
≥50MΩ |
||
Input loop current |
<0.05µA |
||
noise level |
<15µVp-p |
||
Baseline adjustment |
Automatic |
||
Patient leakage Current |
<10µA(220V-240V) |
||
filtering |
Electromyography filtering: 25Hz/30Hz/40Hz Baseline filtering: 0.05 Hz /0.15 Hz /0.25 Hz /0.32Hz/0.5Hz/0.67Hz AC filter: 50Hz/60Hz Low pass filtering: 75Hz,100 Hz,150 Hz |
||
Common mode rejection ratio( CMRR) |
100dB |
||
Record mode |
Automatic: 12CH,6CH×2+1R ,6CH,3CH×4+3R, 3CH×4+1R,,3CH Automatic: 12CH,6CH,3CH,2CH,1CH Rhythm: any rhythm lead connection |
||
Paper speed |
5mm/s ,6.25mm/s,10 mm/s,12.5mm/s, 25mm/s, 50mm/s |
||
Safety standard |
IEC I/CF |
||
Sampling frequency |
Normal 1000sps/channel,Pacing 10000sps/channel |
||
Pacing detection |
≥±2mV ≥±0.1ms |
||
Touchscreen Monitor |
Display screen |
15 inch color LED screen,response time:6ms, 1500nits ultra-brightness, visible in the sunlight |
|
Working Range |
Temperature :0--50℃;Humidity:10%--90%(relativity,Not compressed) |
||
Resolution |
1024*768 |
||
Brightness & Contrast |
400cd/㎡ ; 5000:1 |
||
Touch plate normal working time |
Industrial resistive touchscreen ,20000hours normal working |
||
Touch plate life |
30000000 times normal operation (Tip R0.8mm)
|
||
Advertisement display |
Display |
21” Industrial LED display 、color 16.7M |
|
Working range |
Temperature :0--50℃ Humidity:10%--90%(Ralativity) |
||
Resolution |
1440*900 |
||
Brightness & Contrast |
400cd/㎡ ; 5000:1 |
||
Industrial host computer |
CPU |
Intel® Bay Trail J1900 quad core 2.0G |
|
RAM |
1×notebook RAM dip slot , support DDR3L 1333/1600MHz 4GB |
||
HDD |
TIGO SSD Solid disc 120G |
||
Audio card |
Realtek ALC662, support 5.1 channel |
||
Double display |
VGA1+LVDS(EDP)VGA2+LVDS(EDP)VGA1+VGA2 simultaneous display |
||
Interface |
1×Realtek RTL8111F、6×COM、9× USB、1×LVDS、1×VG、2×10-pin、3× USB 2.0/1. |
||
Others |
|||
ID card reader |
Support ID carder |
||
Brand printer (options) |
HP P1106 A4 Laser printer |
||
Physical Specifications |
|||
Kiosk size |
Height 240cm* length190cm* width 65cm |
||
Data output interface |
LAN interface |
||
Power Voltage |
AC 220V (50Hz/60Hz) |
||
Rating Power |
Max 200W |
||
Working humidity range (Storage temperature ) |
5℃~45℃(-10℃~+60℃) |
||
Kiosk Weight |
About 100kg |
OS :Self-service health check operation system
Register & Log in |
Register |
Registration by using ID cards, complete cell phone number information, or enter cell phone numbers, improve ID and name information, and synchronize data docking with cloud platform. |
Log in |
Users use the ID card, or entering the mobile phone number, or the ID card number to login. Users can complete the physical measurement, read the medical examination report and the appraisal report, print the report and so on, inter connection with the platform data. |
|
Body Health Check |
Height & Weight |
Detect method introduction, intelligent measurement of height and weight, automatic calculation of BMIs, judgement of BMI level, support voice prompts, upload measurement data to the platform. |
Body fat |
Detect method introduction, body fat (body fat ratio, body moisture rate, basal metabolism) is measured based on height and weight data, body mass index and body shape measurement result grade are judged, support voice, upload measurement data to the platform. |
|
Body temperature |
Detect method introduction, measure body temperature, judge measurement results, support voice prompt, upload, measuring data to the platform. |
|
Blood pressure |
Detect method introduction, measure blood pressure, judge blood pressure level, support voice prompt, upload measuring data to the platform. |
|
Blood Oxygen |
Detect method introduction, measure pulse oxygen, judge measurement result, support voice prompt, upload measurement data to platform. |
|
Wait-to-hip ratio |
Detect method introduction, input the waistline and hip circumference manually after the waistline and hip circumference are measured , calculate the waist and hip ratio automatically, judge measurement result, support voice prompt, upload measurement data to platform. |
|
Blood glucose |
Detect method introduction, measure blood glucose, measure fasting, 2 hours postprandial, random blood glucose, support manual input measurement data,judge measurement result, support voice prompt, upload measurement data to platform. |
|
Uric acid |
Detect method introduction, measure uric acid, support manual input measurement data, judge measurement result, support voice prompt, upload measurement data to platform. |
|
Cholesterol
|
Detect method introduction, measure cholesterol, support manual input measurement data, judge measurement result, support voice prompt, upload measurement data to platform. |
|
Report Inquiry |
Health report |
Check the report generated by user's measurement parameters and check the overall list of the data results. Analyze the data and provide targeted health recommendations. |
Assessment report |
Check a report on the periodic health management solutions developed by platform doctors for platform members. |
|
Print report |
Print report |
Print health check report and assessment reports
|
Connection support |
Interface with cloud platform and public health platform
|
Self-service Health Check Kiosk Configurations
No. |
Equipment |
Quantity |
Remarks |
1 |
Self-service health check workstation |
1 |
|
2 |
Industrial computer |
1 |
|
3 |
ID card reader |
1 |
|
4 |
Ultra-sonic height & weight detector |
1 |
|
5 |
Body fat detector |
1 |
|
6 |
Automatic blood pressure detector |
1 |
|
7 |
Infrared blood oxygen detector |
1 |
|
8 |
Infrared temperature detector |
1 |
|
9 |
Blood glucose detector |
1 |
|
10 |
Waistline ruler |
1 |
|
11 |
Advertisement player |
1 |
|
12 |
Thermal printer |
1 |
|
13 |
Laser printer |
1 |
|
14 |
Expert blood pressure stool |
1 |
|
15 |
Blood glucose test paper |
1 |
|
16 |
Thermal printer paper |
10 |
|
17 |
Manual |
1 |
|
18 |
Kiosk OS |
1 |
|